Latest activity by ALK-
ALK commented,
Hello Sweta, in my first post, I've tried to explain what the Diagnostic object is good for within the Anybus CompactCom object model and how to create and delete diagnostic events. If you need det...
-
ALK commented,
Hello Gary, sorry for the late reply, your request slipped through somehow. Something must have gone wrong with the FW download, since both RUN and ERR LEDs lighting up in red means a FATAL error. ...
-
ALK commented,
Official comment Hello, in order to convert CAN bus to Modbus-TCP, I would recommend the Anybus Communicator CAN for Modbus-TCP, p/n AB7319-B.
-
ALK commented,
Official comment Dear Sweta, in the Anybus CompactCom object model, the Diagnostics Object 0x02 serves the purpose of announcing an event to the network. This may be a malfunctioning device or a value exceeding it...
-
ALK commented,
Hello Albert, in the [Connection Manager] section, there is the "Exclusive Owner" connection with this path: "20 04 24 C5 2C 96 2C 64" wherein the 96 and 64 stand for the instance numbers (in hex) ...
-
ALK commented,
Hi Albert, for an explicit message I/O data exchange, you'll need to use e.g. the get_attribute_single 0x0E or the set_attribute_single 0x10 services applied periodically to the Assembly Class 04, ...
-
ALK commented,
You might wanna also take a look at the open source project Ethernet/IP Explorer that could help you disclose the necessary packets (both through Wireshark sniffs and the source itself) to handle E...
-
ALK created an article,
Troubleshooting an Anybus CompactCom 40 in SPI mode
This article gives possible reasons why the communication between your host controller and an Anybus CompactCom 40 (ABCC40) fails. APPLICABLE PRODUCTS Anybus CompactCom 40 in SPI modeABCC dri...
-
ALK commented,
Sounds great, glad I've been of help!
-
ALK commented,
Official comment Hello, I have just quickly created a test setup to verify the behaviour of the HMS POWERLINK XDDFile Uploader. I could observe that the tool, before the actual scan, performs a reset of the POWERL...