Hi Raphael, Only the IO Process Data is shown in the main communication window of the PROFIBUS Master Simulator. Have you mapped all those 16 ADIs as Process Data in your host application? It may b...
-
Komlanさんがコメントを作成しました:
Hi Monesh, No, RMII is not a requirement for communication between the ABCC40 and the host. If the communication interface you would like to use between your host and the ABCC40 is SPI, then you si...
-
Komlanさんがコメントを作成しました:
Hello, The reception trigger byte and the transaction status byte are both triggered by a change in the transaction, however, as you pointed out, they don't provide any information on the specific ...
-
Komlanさんがコメントを作成しました:
Hi Asaad, I'm guessing this issue could be the result of the way your ADI mapping was done. In the ABCC40 PROFINET, there's a limitation to 128 submodules, and in the ADI based configuration, each ...
-
Komlanさんがコメントを作成しました:
Hi Asaad, What do those 128 ADIs amount to in terms of data size? Did you check the value of ABCC_CFG_MAX_PROCESS_DATA_SIZE in abcc_drv_cfg.h?