Peter Wucherer a ajouté un commentaire,
Hi Noah,I try to reproduce it. But I did not see lost data with your filter settings, all messages are received.I send 204800 messages at 1 MBit with nearly 100% bus load and incremented identifier...
-
Peter Wucherer a ajouté un commentaire,
Commentaire officiel Hi Noah,it's an interesting problem. I will try to reproduce it here. But I need some time for this and add then next week more information here.Best regards,Peter
-
Peter Wucherer a ajouté un commentaire,
Hello Ueli,thank you for the confirmation.If there are any questions or problems, then please create here or at our support page a new request.https://support.hms-networks.com/hc/en-usBest regards,...
-
Peter Wucherer a ajouté un commentaire,
Hello Ueli,we created a new version on NuGet it is V 4.1.12.I tested it with .NET Framework 4.8 and .NET 9.https://www.nuget.org/packages/Ixxat.Vci4.StrongName Also, the source code is updated on ...
-
Peter Wucherer a ajouté un commentaire,
Hello Ueli,we found it. A new NuGet-Package will come.In the manifest file the path to the DLL has a leading backslash."\vcinet\arm64\vcinet.arm64.dll"This should be without backslash (for all of t...
-
Peter Wucherer a ajouté un commentaire,
Hello Ueli,it seems I can reproduce it with Visual Studio 2022.Without ClickOnce Security it works ok.With ClickOnce only the EXE in the directory "app.publish" works ok after adding the subdirecto...
-
Peter Wucherer a ajouté un commentaire,
Commentaire officiel Hello Ueli,do you use a ARM64 Windows System?I ask because of this output: "\vcinet\arm64\vcinet.arm64.dll"BTW - the sources for the VCI.NET wrapper is now free available:https://github.com/hms-net...
-
Peter Wucherer a ajouté un commentaire,
Commentaire officiel Hello,the CM CANopen is busy and has no time to answer the download request.If the running application uses SDO transfers, then this block the USB communication. Set the PLC to stopped.You can try ...
-
Peter Wucherer a ajouté un commentaire,
Hi Sahng-Gyu,thank you for sharing the result. Then bitrate 1000000 should be the correct setting.As it is a public forum maybe it can be helping others to bring up their systems.Then enjoy working...
-
Peter Wucherer a ajouté un commentaire,
Hi Sahng-Gyu,I wrote above about that acknowledge flag.You can use 1 CAN channel of the USB-to-CAN V2 and connect it to your sensor.Don't forget the terminating resistors.Then you send one single C...