Compatible Devices
EMCO Flow Processors [g3-emcofp93 | Word]
Verified Device
FP-93 [g3-emcofp93 | Word]
Accessible Data
Core Register Types
| Prefix |
Description |
Type |
| F |
Float Registers |
Real |
| L |
Long Integer Registers |
Long |
Unit / String Information
| Prefix |
Description |
Type |
| S19 |
Temperature Units |
Long |
| S24 |
Pressure Units |
Long |
| S26 |
Density Units |
Long |
| S38 |
Volume Flow Units |
Long |
| S44 |
Mass Flow Units |
Long |
| S49 |
Energy Flow Units |
Long |
| S94 |
Unit Information Block |
Long |
✅ These are string-type values and require proper string tag configuration [g3-emcofp93 | Word]
Analog Inputs / Outputs
| Prefix |
Description |
Type |
| C03–C06 |
Analog Inputs (1–4, mA) |
Real |
| C51 |
Analog Output (mA) |
Real |
Flow & Process Values
| Prefix |
Description |
Type |
| C30 |
Volume Flow |
Real |
| C40 |
Mass Flow |
Real |
| C45 |
Energy Flow |
Real |
| C20 |
Pressure |
Real |
| C10 / C14 |
Temperature #1 / #2 |
Real |
Averaged Values
| Prefix |
Description |
| C46 |
Avg. Energy Flow |
| C41 |
Avg. Mass Flow |
| C21 |
Avg. Pressure |
| C11 / C15 |
Avg. Temperature |
| C31 |
Avg. Volume Flow |
Min / Max Values
Examples:
| Prefix |
Description |
| C33 |
Max Volume Flow |
| C32 |
Min Volume Flow |
| C13 / C17 |
Max Temperatures |
| C12 / C16 |
Min Temperatures |
| C23 / C22 |
Max / Min Pressure |
Calculated Process Properties
| Prefix |
Description |
| C25 |
Density |
| C66 |
Compressibility Factor |
| C67 |
Supercompressibility Factor |
| C65 |
Reynolds Number |
| C68 / C69 |
Enthalpy |
| C64 |
Viscosity |
| C27 |
Specific Volume |
Velocity & Frequency
| Prefix |
Description |
| C63 |
Line Velocity |
| C60 |
Raw Velocity |
| C07 |
Frequency (Hz) |
Totalizers
| Prefix |
Description |
| C52 / C53 |
Totalizer #1 (Forward) |
| C54 / C55 |
Totalizer #2 (Reverse) |
| C57 / C59 |
Scale Factors |
| C56 / C58 |
Totalizer Assignments |
Control / Maintenance Commands
| Prefix |
Description |
Type |
| C91 |
Clear Faults |
Long |
| C92 |
Clear Statistics |
Long |
| C93 |
Clear Totalizers |
Long |
Faults & Status
| Prefix |
Description |
| C90 |
Fault Flags |
| C08 |
Flow Direction (1=Fwd, 0=Rev) |
Time / Event Tracking
| Prefix |
Description |
| C70 |
Current Time |
| C74 |
Power Failure Time |
| C72 |
Time Stats Cleared |
| C81–C85 |
Alarm/Fault Times |
Notes
- ❗ Configuration constants cannot be modified via this protocol [g3-emcofp93 | Word]
- 📌 For
<String> items:
Cable Information
RS232 Serial Connection
| **EMCO FP-93** |
**Signal** |
**G3** |
| 3 |
Tx → Rx |
2 |
| 2 |
Rx ← Tx |
5 |
| 5 |
0V |
3/4 |
Summary
This driver provides extensive process monitoring capabilities for flow systems, including:
- Real-time flow, pressure, temperature, and energy measurements
- Calculated properties like density, viscosity, compressibility
-
Statistical tracking (min/max/average)
- Totalization and event timing
- System diagnostics via fault flags and timestamps
👉 Practical takeaway:
- This is a high-data-density process driver
- Best used in flow / energy monitoring applications
- Requires careful tag setup (especially for string and real values)
- Limited write capability — mostly monitoring-focused with selective control/reset functions