Compatible Devices
FLOWCOM INSTRUMENTS
Verified Device
FLOWCOM S8
Accessing Data
Crimson allows entry of Instruction Codes 20H – FFH. Definition of each Instruction Code is dependant upon the FlowCom Instrument device configuration and/or programming. Please note string arrays are not fully compatible with this driver.
Read Operations
All string tags associated with read operations should be set to a length of 80 characters. If using string arrays to divide a string in to sub strings, the arrays read policy should be set to “Read Whole Array”.
Write Operations
All write only operations should be assigned to a tag designated as such. It is always good practice to clear a string before writing a similar string.
Cable Information
| **G3 RS232 Port** | **FlowCom Connector** |
|---|---|
| Pin 2 – RX | B |
| Pin 3 – COMM | A |
| Pin 5 - TX | D |