This procedure is relevant when a password is lost for the Anybus Defender and the device needs to be reset. NOTE: all configuration on the device will be lost and not recoverable.
APPLICABLE PRODUCTS
Anybus Defender Series 4000 and up
PRE-REQUISITES
USB drive and Physical Access to the Anybus Defender
IN THIS ARTICLE
- Put the config file "config-factory-default.xml" on a USB drive with normal formatting e.g. FAT32.
- Insert the USB-rive in any of the 2 ports on the Defender.
- Power cycle, or reboot and the device's configuration will be flashed with this configuration file.
- Note that all configuration previously present on the unit will be removed, however the license will remain.
- After reboots connect tot default IP 192.168.200.1 and use the default username and password. (admin/defender)