This procedure is relevant when a password is lost for the Anybus Defender and the device needs to be reset. NOTE: all configuration on the device will be lost and not recoverable.
APPLICABLE PRODUCTS
Anybus Defender Series 4000 and up
PRE-REQUISITES
USB drive and Physical Access to the Anybus Defender
Download file "config-factory-default.xml" here
- Put the config file "config-factory-default.xml" on a USB drive with normal formatting e.g. FAT/FAT32.
- Insert the USB-drive in any of the USB ports on the Defender.
- Power cycle, or reboot and the device's configuration will be flashed with this configuration file.
- Note that all configuration previously present on the unit will be removed, however the license will remain.
- After reboots connect to default IP https://192.168.200.1/ and use the default username and password (admin/defender) to gain access again.
- You can restart the setup wizard from the menu System -> Setup Wizard
EXPERT NOTES
Any XML config export can be used to perform this procedure. Note that the Admin password needs to be set to the following string "<bcrypt-hash>$2y$10$XRnCAj7oU6x8iVzf77A1y.7EOTMX3QOKwOpkVbOseTMOs1oE1UvgC</bcrypt-hash>" to represent the default "defender"
Like in the <user> section below:
<user>
<name>admin</name>
<descr>System Administrator</descr>
<scope>system</scope>
<groupname>admins</groupname>
<bcrypt-hash>$2y$10$XRnCAj7oU6x8iVzf77A1y.7EOTMX3QOKwOpkVbOseTMOs1oE1UvgC</bcrypt-hash>
<uid>0</uid>
<priv>user-shell-access</priv>
</user>
© HMS Networks AB 2026