This article describes the issues you need to pay attention to when accessing the Communicator built-in web interface through browser.
APPLICABLE PRODUCTS
All Anybus Communicator
QUESTION
The built-in web interface of Anybus Communcator cannot be accessed.
ANSWER
- Check the connection between computer and gateway.
- Check the computer IP address within the same IP address range as the Communicator IP address .The default IP address of the gateway configuration port is 192.168.0.10. Run the ping command on PC to check the network connectivity.
- Enter the IP address of the gateway configuration port at the browser. If the access was denied, please check the security switch status, push the toggle towards the Communicator back.
ADDITIONAL INFO
Reset Anybus Communicator to factory settings
How to upgrade firmware for Anybus Communicator