Atlas2 and Ethertap network diagnostic
Hi everyone, we have atlas2 and ethertap (100mbps) and the license for Ethernet/IP, Profinet and Modbusif we measurement of Profinet, we can see so much information like topology, detail error at r...
-
djoneddd hat einen Post erstellt
ABC3090 - FATAL ERROR - PROFINET to MODBUS/RTU
Hi Everyone, my customer have problem with ABC3090 it suddenly have fatal error it already 3x at the last week, after reboot from power it is going back normal. gateway works for 24h/7d for almost...
-
djoneddd hat einen Kommentar hinterlassen
Hi Amir, Actually, we can add, delete or re-order position of node from "Network Manager"but for bar graph display only have option display base-on address or base-on level measurementif we delete ...
-
djoneddd hat einen Kommentar hinterlassen
Update: it works fine if I connect it from Q71E71-100we just need to crosscheck the assignment IP of module, network number and station numberthe default for MC port will be: UDP=5000/5001; TCP:500...
-
djoneddd hat einen Kommentar hinterlassen
Hi Franziska, Thank you for the link, i will try it next week on site, i hope it can work properlyi will update here with documentation if it works Best regards, Joned
-
djoneddd hat einen Kommentar hinterlassen
Hi ALK, Thank you for your recomendation,After i change the address, it's working properly now Best Regards, Joned
-
djoneddd hat einen Post erstellt
ABC4091 - Siemens S7-300 [profibus] with S7-1200 [profinet]
BeantwortetHi everyone, I have network Profinet [S7-1200] with Profibus [S7-300], so i use ABC4091 for exchange dataFor profinet side it works fine, i can send data and can monitored from IO diagnostic on ABC...
-
djoneddd hat einen Post erstellt
FLEXY 205 WITH MITSUBISHI QJ71E71-100
AbgeschlossenHi everyone, i want to pooling data from Mitsubishi Q170MSCPU [basically it was integrated cpu Q03UDCPU with motion cpu] through QJ71E71-100 (ethernet module)But i can't found option for MC protoc...
-
djoneddd hat einen Kommentar hinterlassen
Hi Ralf, Thank you for the feedback,Is that mean Profihub FO only works on base network profibus not profinet?So if the network already have FO from Profinet we can't use it right?Do you have exper...
-
djoneddd hat einen Post erstellt
Anybus Profihub With Fiber Optic
Hi everyone, can i use Profihub (with fiber optic) as network converter from Profibus DP to Fiber Optic Ring?for example the PLC as master connect to DP connector at profihub, and the fiber optic f...